If your RV water heater heats on propane but not on electric, the problem is almost always on the 120V side. The usual causes are a switch or breaker that’s off, a weak shore power source, a tripped ECO reset or a burned-out heating element. The gas burner and igniter play no part in electric mode, so start with power and work toward the element.

Why Does My RV Water Heater Work on Propane but Not Electric?
Propane mode and electric mode use different parts. When gas works, the burner, igniter and gas valve are fine. The fault is in the parts that only electric mode uses. These are the most common causes of an RV water heater not working on electricity, roughly in order of how likely they are:
- The electric water heater switch is off, or its breaker in the 120V AC panel has tripped
- No 120V power: a tripped pedestal breaker or GFCI, an overloaded generator, or an inverter that doesn’t feed the water heater circuit
- A tripped ECO (high-limit) switch
- A burned-out or corroded heating element
- A failed electric thermostat
- A bad control board or relay (Atwood/Dometic models)
- A loose or burned wire in the junction box
- An open bypass valve or a faulty check valve (lukewarm water rather than none)
A pilot that keeps going out or a bad igniter is a propane-side problem. Neither one stops the 120V element from heating.
Before You Start: Never Run Electric Mode With an Empty Tank
Running the element without water around it is called dry firing. It can burn out a new element within seconds. Suburban warns that the element switch must be off and the tank full before power is applied, or the element will burn out.
- Make sure the bypass valves are set to normal (not bypass).
- Turn on city water or the water pump.
- Open a hot water faucet inside the RV.
- Leave it open until water flows steadily with no sputtering air. This means the tank is full.
- Only then turn on the electric switch.
How to Fix an RV Water Heater Not Working on Electric
You can still heat water on propane while you sort this out. Work through these checks in order, since the first ones are the quickest and most common.
1. Check the Water Heater Switch and the 120V Breaker
Electric mode has its own switch, separate from the gas switch. Depending on the model, it may be on the inside control panel or behind the outside access door. Make sure it’s on.
Next, open the RV’s 120V AC breaker panel and find the water heater breaker. A power surge or short can trip it. Any owner can reset it: switch it fully off, then back on. If it trips again right away, the element or wiring may be shorted. Stop there and have an RV technician check it.
A breaker and a fuse are two separate devices. A tripped AC breaker cuts 120V to the element. It does not blow the 12V fuse. The 12V fuse protects the DC controls, which include the gas ignition. On some Atwood/Dometic models it also protects the electric-mode relay or board. A blown 12V fuse would normally stop gas mode too, so it’s an unlikely cause when propane still works.
Read Also: How to Know Your RV Water Heater Switch On or Off?
2. Confirm You Have 120V Shore, Generator or Inverter Power
The electric element runs on 120V AC from shore power, a generator or a large inverter. It does not run on 12V battery power, so low house batteries won’t stop it directly. Very low 12V voltage only matters on models that use a 12V relay or control board to switch the element, such as some Atwood/Dometic units.
A 1,440 W element draws about 12 amps at 120V. A 30A RV service (about 3,600 W) or a 50A service can run it easily. Problems usually come from one of these:
- Too many loads at once. On 30A, running the water heater with an air conditioner, microwave or space heater can trip the main or pedestal breaker.
- A weak or tripped pedestal. Check the campground pedestal breaker and any GFCI outlet you’re plugged into.
- A small or overloaded generator. It may not handle the element plus other loads.
- An inverter that doesn’t feed the water heater circuit. Many inverters only power certain outlets, so the element gets nothing when you’re off shore power.
Read Also: Why Does My Rv Water Heater Sound Like A Jet Engine?
3. Reset the ECO (High-Limit) Switch
The ECO is a safety switch that cuts power to the element if the water gets too hot. On Suburban SW10DE, SW12DE and SW16DE units, water above 180°F trips the manual reset. The water must cool below 110°F before pushing reset brings the element back (Suburban manual).
To reset it safely, turn off the electric switch and breaker first. Let the water cool. Then open the outside access door and press the red reset button firmly. Turn power back on. If the ECO keeps tripping, the thermostat may be stuck on. That needs repair, not repeated resets.
Where is the reset button on a Suburban RV water heater? It’s on the electric thermostat/ECO assembly behind the outside access door. Atwood/Dometic placement varies by model, so check your manual if you don’t see it there.
Read Also: Where is the RV Water Heater Reset Button and How To Use It?
4. Test the Electric Heating Element
The element turns electricity into heat. It has a limited lifespan and can corrode over time. If the heater runs on electric without water, the element can fail in seconds.
On Suburban units, the element is usually reached from the outside access door. On Atwood and Dometic units, its location can differ, so check your manual.
Check for voltage first (power on). If you’re comfortable around live 120V, set the multimeter to AC volts. Touch the leads only to the element terminals or the control board’s output terminals. Use insulated leads, keep one hand away, and don’t touch bare metal. A reading near 120V with a cold tank points to the element. No voltage points to the switch, thermostat, ECO, board or wiring. If you’re not comfortable testing live circuits, skip this step and call a technician.
Then test resistance (power off):
- Turn off the electric switch and the water heater breaker.
- Remove the wires from the element terminals.
- Set your multimeter to ohms (Ω).
- Put the leads on the two element terminals.
- Read the result. A good 1,440–1,500 W element reads about 9.6–10 ohms. An open (infinite) reading means the element is burned out.
- Check for a short to ground. Put one lead on a terminal and the other on the element’s metal flange or the tank. Any reading other than open means the element is shorted and should be replaced.
How Do You Replace an RV Water Heater Element?
- Turn off the electric switch, the water heater breaker and the gas.
- Turn off the water pump or city water.
- Open a hot faucet and the pressure relief valve to release pressure.
- Remove the drain plug or anode and let the tank drain fully. Make sure the water has cooled first.
- Disconnect the element wires.
- Unscrew the old element with an element socket that fits your model.
- Install the new element with a new gasket or the thread sealant the maker specifies, and reconnect the wires.
- Reinstall the drain plug or anode, then refill and purge air as described above.
- Check for leaks, then turn the electric switch back on.
Read Also: RV Water Heater Drain Plug Size: Everything you need to know
5. Replace a Faulty Electric Thermostat
The electric thermostat decides when the element turns on. When the tank is cold, it sends 120V AC straight to the element. Some Atwood/Dometic models route that power through a 12V relay. There is no flame or pilot in electric mode.
If the thermostat fails, no power reaches a good element, so the water stays cold. Turn off all power first. Then remove the access panel, label and disconnect the thermostat wires, and install a replacement that matches your heater model.
6. Check the Control Board or Relay (Atwood/Dometic)
Don’t replace the igniter for this problem. The igniter or DSI board only lights the propane burner. For Atwood/Dometic heaters that work on gas but not electric, Dometic points to three likely failures: the circuit board, the relay or the element.
On these models, a 12V signal closes a relay that switches 120V to the element. A failed relay or board, or very low 12V voltage, can stop electric mode while gas still works. If the element tests good and 120V reaches the board but not the element, the board or relay is the likely cause.
Also check the junction box for loose, burned or melted wires.
Read Also: How to Troubleshoot & Fix RV Tankless Water Heater Problems?
7. Lukewarm Water? Check the Bypass and Check Valve
If the water is warm but never hot, cold water may be mixing into the hot line. A bypass valve left partly open after winterizing is a common cause. Set all bypass valves to normal.
A faulty check valve can also let cold water cross into the hot side. To inspect it, turn off the water and drain the tank first. Then disconnect the valve, check it for damage and replace it if needed.
Read Also: 7 Easy Solutions For RV Water Heater Igniter Not Clicking
When Should You Call an RV Technician?
Get professional help in any of these cases:
- The breaker trips again right after you reset it.
- You find burned or melted wiring.
- The control board needs replacing.
- You’re not comfortable testing live 120V circuits.
FAQs
Frequently having trouble with working your RV water heater on electricity is not ideal. Here are answers to a few related questions.
Do RV Water Heaters Run Better On Propane Or Electric?
Propane usually heats faster. The burner puts out more BTUs than a roughly 1,440 W element, which makes about 4,900 BTU/h. Once the water is hot, electric doesn’t keep it hot any longer, because both modes hold temperature with a thermostat. Electric is handy when you have hookups and want to save propane.
How Do I Switch The RV Water Heater From Propane to Electric?
First make sure the tank is full. Turn off the gas switch, then turn on the electric switch. Depending on the model, the electric switch is on the inside control panel or behind the outside access door. You also need 120V power from shore, a generator or an inverter that feeds the water heater circuit.
Read Also: 8 Common Causes of a DSI Fault Light on RV Water Heater
What Happens If You Turn On an RV Water Heater Without Water?
In electric mode, the element dry fires and can burn out almost at once. It will then read open on a multimeter and must be replaced. Always fill the tank and purge the air before turning on the electric switch.
Why Is My Electric Water Heater Getting Power but Not Heating?
If the heater gets 120V but doesn’t heat, check these parts:
- A tripped ECO/high-limit
- A failed electric thermostat
- A burned-out element
- A bad relay or control board (Atwood/Dometic)
- A loose wire in the junction box
Start with the ECO reset, then test the element.
Conclusion
When propane works but electric doesn’t, skip the gas parts and follow the 120V path. Check the switch and breaker, then your power source, the ECO reset, the element, the thermostat and, on Atwood/Dometic units, the board or relay. Always fill the tank before power goes on, and regular maintenance helps the element last longer.
Read Also: 5 Common Reasons Why Your RV Water Heater Won’t Shut Off